HD-Wave SeriesSingle-Phase

SolarEdge SE3800H-US

HD-Wave Series · 3.8 kW

Common Issues

Arc Fault Detection (AFD) Trips

The inverter detects potential arc faults in the DC string and shuts down to protect the system. Check wiring connections on modules.

String Imbalance

Uneven power output from different strings due to shading, soiling, or module mismatch. Reduces overall system efficiency.

Temperature Derating

In extreme heat, the inverter reduces output to prevent overheating. Performance returns to normal when temperature drops.

Wi-Fi Connection Drops

Intermittent loss of Wi-Fi connectivity to monitoring system, especially in homes with weak signal coverage.

Key Specifications

Power Rating3.8 kW AC
Input Voltage Range150V - 480V DC
Max Input Current18A per string
Efficiency97.4%
Weight28 lbs

Common Error Codes

AFD

Arc Fault Detected in DC string

Critical
12

Grid voltage out of range

Warning
16

Insulation fault detected

Critical
68

Transformer primary over-temperature

Warning

Check Your SE3800H-US Health

Works with any SolarEdge inverter — run a free health check in 30 seconds.

Check Your System Now →

Works with any SolarEdge inverter — run a free health check in 30 seconds.